Inappropriate Nasopharyngeal Sampling for SARS-CoV-2 Detection Is a Relevant Cause of False-Negative Reports
Articolo
Data di Pubblicazione:
2020
Citazione:
Inappropriate Nasopharyngeal Sampling for SARS-CoV-2 Detection Is a Relevant Cause of False-Negative Reports / Piras, A.; Rizzo, D.; Uzzau, S.; De Riu, G.; Rubino, S.; Bussu, F.. - In: OTOLARYNGOLOGY-HEAD AND NECK SURGERY. - ISSN 0194-5998. - (2020), p. 194599820931793. [10.1177/0194599820931793]
Abstract:
Reverse transcriptase polymerase chain reaction (RT-PCR) detection of SARS-CoV-2 mRNA on nasopharyngeal swab is the standard for diagnosing active COVID-19 disease in asymptomatic cases and in symptomatic patients without the typical radiologic findings. For the present COVID-19 outbreak in Italy, we describe 4 symptomatic patients with negative RT-PCR results at the first nasopharyngeal swab, which became positive when collected a few hours later by an otolaryngologist. All the patients showed nasal obstruction. The present report suggests that inadequate nasopharyngeal sampling performed by untrained operators in the presence of nasal obstruction can be a relevant case of false-negative findings at RT-PCR, with a clear negative impact on the efforts to contain the current outbreak.