  1. Pubblicazioni

Accuracy of esophageal pressure to assess transpulmonary pressure during mechanical ventilation

Articolo
Data di Pubblicazione:
2016
Citazione:
Accuracy of esophageal pressure to assess transpulmonary pressure during mechanical ventilation / Terragni, P., Mascia, L., Fanelli, V., Biondi‑zoccai, G., Ranieri, V.M.. - In: INTENSIVE CARE MEDICINE. - ISSN 1432-1238. - 43:1(2016), pp. 142-143. [10.1007/s00134-016-4589-8]
Abstract:
During passive mechanical ventilation, pressure applied to the respiratory system includes the pressure required to inflate the lung (trans-pulmonary pressure) and the chest wall (pleural pressure). Esophageal pressure has been proposed as a surrogate for pleural pressure but controversies exist on the way to derive the values required to calculate trans-pulmonary pressure. Ex-vivo lung perfusion has been proposed to optimize organ function before transplantation. These setting may therefore allow the comparison of values of trans-pulmonary pressure from the lungs outside the thorax (during the ex-vivo lung perfusion) with values obtained from the same lungs inside the thorax (after transplantation). We try to identify the method to derive esophageal pressure that provide the “in-vivo” assessment of trans-pulmonary pressure closer to the “ex-vivo” measurement of trans-pulmonary pressure.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
transpulmonary pressure, Ex vivo lung perfusion (EVLP), Esophageal pressure, mechanical ventilation,
Elenco autori:
Terragni, Pierpaolo; Mascia, L.; Fanelli, V.; Biondi‑zoccai, G.; Ranieri, V. M.
Autori di Ateneo:
TERRAGNI Pierpaolo
Link alla scheda completa:
https://iris.uniss.it/handle/11388/165605
Link al Full Text:
https://iris.uniss.it//retrieve/handle/11388/165605/246425/Terragni_accuracy_2016.pdf
Pubblicato in:
INTENSIVE CARE MEDICINE