Skip to Main Content (Press Enter)

Logo UNISS
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze

Logo UNISS

|

UNIFIND

uniss.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze
  1. Pubblicazioni

A high sensitivity wide bandwidth spectral system for multiple K-edge imaging

Articolo
Data di Pubblicazione:
2024
Citazione:
A high sensitivity wide bandwidth spectral system for multiple K-edge imaging / Perion, P.; Brombal, L.; Delogu, P.; di Trapani, V.; Menk, R. H.; Oliva, P.; Arfelli, F.. - In: JOURNAL OF PHYSICS D. APPLIED PHYSICS. - ISSN 0022-3727. - 57:35(2024). [10.1088/1361-6463/ad4f9b]
Abstract:
Spectral K-edge subtraction (SKES) is an imaging technique that takes advantage of the sharp rise in the mass attenuation coefficient of specific elements within an object at their K-edge to produce separate and quantifiable distributions of each element. In this paper, a high-sensitivity and wide bandwidth SKES imaging system for computed tomography applications on biological samples is presented. X-ray images are acquired using a wide and continuous energy spectrum that encompasses the absorption edges of the target materials. System characterization shows that high energy resolution (approximately 3 x 10 - 3 ) and unprecedented large energy bandwidth (around 15%) are achieved over a field-of-view of several centimeters. Imaging results obtained on contrast elements relevant for biomedical applications, namely silver, iodine, xenon, and barium, demonstrate the system sensitivity to concentrations down to 0.5 mg ml-1. The achievement of a large energy bandwidth allowed the simultaneous imaging of the K-edges of iodine, xenon, and barium and provided an accurate concentration estimation and distinction of co-localized contrast elements, leading the way for future simultaneous cardiovascular (iodine), pulmonary (xenon), and gastrointestinal/inflammatory (barium) imaging applications.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
spectral x-ray imaging; spectral tomography; multiple K-edge; energy dispersive Laue
Elenco autori:
Perion, P.; Brombal, L.; Delogu, P.; di Trapani, V.; Menk, R. H.; Oliva, P.; Arfelli, F.
Link alla scheda completa:
https://iris.uniss.it/handle/11388/335510
Pubblicato in:
JOURNAL OF PHYSICS D. APPLIED PHYSICS
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.2.0