Safety and Efficacy of Ab Interno XEN 45 Gel Stent in Patients with Glaucoma and High Myopia

Articolo
Data di Pubblicazione:
2023
Citazione:
Safety and Efficacy of Ab Interno XEN 45 Gel Stent in Patients with Glaucoma and High Myopia / Sacchi, Matteo; Fea, Antonio M; Monsellato, Gianluca; Tagliabue, Elena; Villani, Edoardo; Ranno, Stefano; Nucci, Paolo. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - 12:7(2023). [10.3390/jcm12072477]
Abstract:
This study reports on the safety and efficacy of Xen 45 in patients with glaucoma and high myopia. It was a retrospective study including patients with high myopia (>6D) who underwent Xen implant with 2 years of follow-up. The primary outcome was to report the incidence of hypotony (IOP <= 5 mmHg) and hypotony-related complications. Patients with high myopia treated with mitomycin-C-augmented trabeculectomy were included as a control group. We included 14 consecutive patients who underwent Xen implant (seven eyes) and trabeculectomy (seven eyes). The mean myopia was -14.71 +/- 5.36 and -15.07 +/- 6.11 in the trabeculectomy and Xen groups, respectively (p > 0.05). The success rate and the mean IOP at 1 and 2 years from the intervention were statistically comparable between the two groups. The group undergoing trabeculectomy showed a higher incidence of hypotony (six eyes (85.71%) vs. two eyes (28.57%)) and hypotony maculopathy (three eyes (42.86%) vs. zero eyes (0%)) and required more postoperative procedures. Patients with high myopia were at higher risk of hypotony-related complications after trabeculectomy. The Xen implant can achieve an IOP control comparable to trabeculectomy with a significantly better safety profile and can be considered as an option for the management of patients with high myopia and glaucoma.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
Xen; glaucoma; glaucoma surgery; hypotony; hypotony maculopathy; stent gel implant; trabeculectomy
Elenco autori:
Sacchi, Matteo; Fea, Antonio M; Monsellato, Gianluca; Tagliabue, Elena; Villani, Edoardo; Ranno, Stefano; Nucci, Paolo
Autori di Ateneo:
SACCHI Matteo
Link alla scheda completa:
https://iris.uniss.it/handle/11388/326854
Link al Full Text:
https://iris.uniss.it//retrieve/handle/11388/326854/352492/36.%202023.%20JCM%20XEN%2045%20in%20Eyes%20with%20High%20Myopia.pdf
Pubblicato in:
JOURNAL OF CLINICAL MEDICINE