Skip to Main Content (Press Enter)

Logo UNISS
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze

Logo UNISS

|

UNIFIND

uniss.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze
  1. Pubblicazioni

Icp-ms determination of 23 elements of potential health concern in liquids of e-cigarettes. Method development, validation, and application to 37 real samples

Articolo
Data di Pubblicazione:
2021
Citazione:
Icp-ms determination of 23 elements of potential health concern in liquids of e-cigarettes. Method development, validation, and application to 37 real samples / Mara, A.; Langasco, I.; Deidda, S.; Caredda, M.; Meloni, P.; Deroma, M.; Pilo, M. I.; Spano, N.; Sanna, G.. - In: MOLECULES. - ISSN 1420-3049. - 26:21(2021), p. 6680. [10.3390/molecules26216680]
Abstract:
The lack of interest in the determination of toxic elements in liquids for electronic cigarettes (e-liquids) has so far been reflected in the scarce number of accurate and validated analytical methods devoted to this aim. Since the strong matrix effects observed for e-liquids constitute an exciting analytical challenge, the main goal of this study was to develop and validate an ICP-MS method aimed to quantify 23 elements in 37 e-liquids of different flavors. Great attention has been paid to the critical phases of sample pre-treatment, as well as to the optimization of the ICP-MS conditions for each element and of the quantification. All samples exhibited a very low amount of the elements under investigation. Indeed, the sum of their average concentration was of ca. 0.6 mg kg−1. Toxic elements were always below a few tens of a µg per kg−1 and, very often, their amount was below the relevant quantification limits. Tobacco and tonic flavors showed the highest and the lowest concentration of elements, respectively. The most abundant elements came frequently from propylene glycol and vegetal glycerin, as confirmed by PCA. A proper choice of these substances could further decrease the elemental concentration in e-liquids, which are probably barely involved as potential sources of toxic elements inhaled by vapers.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
E-cigarettes; E-liquids; ICP-MS; Toxic elements; Trace elements; Health Impact Assessment; Mass Spectrometry; Pressure; Quality Control; Reproducibility of Results; Temperature; Electronic Nicotine Delivery Systems
Elenco autori:
Mara, A.; Langasco, I.; Deidda, S.; Caredda, M.; Meloni, P.; Deroma, M.; Pilo, M. I.; Spano, N.; Sanna, G.
Autori di Ateneo:
DEROMA Mario Antonello
LANGASCO Ilaria
PILO Maria Itria
SANNA Gavino
SPANO Nadia
Link alla scheda completa:
https://iris.uniss.it/handle/11388/277361
Pubblicato in:
MOLECULES
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0