Low contrast imaging with a GaAs pixel digital detector

Articolo
Data di Pubblicazione:
2000
Citazione:
Low contrast imaging with a GaAs pixel digital detector / Amendolia, Salvator Roberto; Bisogni, Maria Giuseppina; Bottigli, Ubaldo; Delogu, Pasquale; Dipasquale, Giovanna; Faucci Giannelli, Michele; Maestro, Paolo; Pernigotti, Elena; Rosso, Valeria; Stumbo, Simone; Ciocci, Maria Agnese; Fantacci, Maria Evelina; Marzulli, Vincenzo M.; Stefanini, Arnaldo. - In: IEEE TRANSACTIONS ON NUCLEAR SCIENCE. - ISSN 0018-9499. - 47:4(2000), pp. 1478-1482. [10.1109/23.873000]
Abstract:
A digital mammography system based on a GaAs pixel detector has been developed by the INFN (Istituto Nazionale di Fisica Nucleare) collaboration MED46. The high atomic number makes the GaAs a very efficient material for low energy X-ray detection (10-30 keV is the typical energy range used in mammography). Low contrast details can be detected with a significant dose reduction to the patient. The system presented in this paper consists of a 4096 pixel matrix built on a 200 μm thick semi-insulating GaAs substrate. The pixel size is 170×170 μm2for a total active area of 1.18 cm2. The detector is bump-bonded to a VLSI front-end chip which implements a single-photon counting architecture. This feature allows to enhance the radiographic contrast detection with respect to charge integrating devices. The system has been tested by using a standard mammographic tube. Images of mammographic phantoms will be presented and compared with radiographs obtained with traditional film/screen systems. Monte Carlo simulations have been also performed to evaluate the imaging capability of the system. Comparison with simulations and experimental results will be shown.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
Monte Carlo methods; mammography; semiconductor counters
Elenco autori:
Amendolia, Salvator Roberto; Bisogni, Maria Giuseppina; Bottigli, Ubaldo; Delogu, Pasquale; Dipasquale, Giovanna; Faucci Giannelli, Michele; Maestro, Paolo; Pernigotti, Elena; Rosso, Valeria; Stumbo, Simone; Ciocci, Maria Agnese; Fantacci, Maria Evelina; Marzulli, Vincenzo M.; Stefanini, Arnaldo
Link alla scheda completa:
https://iris.uniss.it/handle/11388/262840
Link al Full Text:
https://iris.uniss.it//retrieve/handle/11388/262840/194688/Amendolia_S_Articolo_2000_Low.pdf
Pubblicato in:
IEEE TRANSACTIONS ON NUCLEAR SCIENCE