Skip to Main Content (Press Enter)

Logo UNISS
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze

Logo UNISS

|

UNIFIND

uniss.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze
  1. Pubblicazioni

Red Cell Distribution Width (RDW) and Complete Blood Cell Count-Derived Measures in Non-Arteritic Anterior Ischemic Optic Neuropathy

Articolo
Data di Pubblicazione:
2021
Citazione:
Red Cell Distribution Width (RDW) and Complete Blood Cell Count-Derived Measures in Non-Arteritic Anterior Ischemic Optic Neuropathy / Pinna, Antonio; Carlino, Paola; Serra, Rita; Boscia, Francesco; Dore, Stefano; Carru, Ciriaco; Zinellu, Angelo. - In: INTERNATIONAL JOURNAL OF MEDICAL SCIENCES. - ISSN 1449-1907. - 18:10(2021), pp. 2239-2244. [10.7150/ijms.53668]
Abstract:
Purpose: To assess the role of complete blood cell count (CBC) dimensional indices and CBC-derived measures in non-arteritic anterior ischemic optic neuropathy (NA-AION). Methods: In this retrospective case-control survey, 37 newly diagnosed NA-AION patients and 37 sex- and age-matched cataract controls were enrolled in 2017-2018. On the same day of NA-AION diagnosis, a blood sample was collected and CBC was determined using an automatic blood counter. CBC dimensional indices, such as mean platelet volume (MPV) and red cell distribution width (RDW), and CBC-combined indices, including neutrophil/lymphocyte ratio (NLR), derived NLR [dNLR = neutrophils/(white blood cells - neutrophils)], and platelet/lymphocyte ratio (PLR), were evaluated. Erythrocyte sedimentation rate (ESR) was also measured. Results: Mean platelet count, median MPV, RDW, NLR, and dNLR were 221±48 x 109/L, 8.2 fL (IQR=7.6-8.9), 13% (IQR=12-14.5), 2.50 (IQR=1.77-3.06), and 1.73 (IQR=1.31-2.07) in NA-AION patients and 248±56 x 109/L, 7.60 fL (IQR=7.05-8.25), 12% (IQR=11.6-13), 1.95 (IQR=1.43-2.49) and 1.36 (IQR=1.07-1.69) in controls. NA-AION patients showed significantly lower platelet count (p=0.03) and significantly higher median values of MPV (p=0.01), RDW (p=0.015), NLR (p=0.03), and dNLR (p=0.01). Multivariate logistic regression models disclosed a significant correlation only between higher levels of RDW and NA-AION (p≤0.05). The attributable risk of the association between NA-AION and RDW was 33%. Conclusions: Results suggest that RDW may be somehow involved in the pathogenesis of NA-AION. However, high-quality cohort studies are warranted to confirm whether, or not, an altered RDW may be considered a potential biomarker of this vascular disorder affecting the optic nerve.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
Mean Platelet Volume (MPV), Red Cell Distribution Width (RDW), Neutrophil/Lymphocyte Ratio (NLR); Non-arteritic Anterior Ischemic Optic Neuropathy (NA-AION); derived NLR (dNLR)
Elenco autori:
Pinna, Antonio; Carlino, Paola; Serra, Rita; Boscia, Francesco; Dore, Stefano; Carru, Ciriaco; Zinellu, Angelo
Autori di Ateneo:
CARRU Ciriaco
DORE Stefano
PINNA Antonio
SERRA Rita
ZINELLU Angelo
Link alla scheda completa:
https://iris.uniss.it/handle/11388/246495
Link al Full Text:
https://iris.uniss.it//retrieve/handle/11388/246495/175283/Int%20J%20Med%20Sci%202021%20RDW%20&%20NA-AION.pdf
Pubblicato in:
INTERNATIONAL JOURNAL OF MEDICAL SCIENCES
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0