A multicenter randomized controlled trial using a novel collagen membrane for guided bone regeneration at dehisced single implant sites: Outcome at prosthetic delivery and at 1-year follow-up

Articolo
Data di Pubblicazione:
2019
Citazione:
A multicenter randomized controlled trial using a novel collagen membrane for guided bone regeneration at dehisced single implant sites: Outcome at prosthetic delivery and at 1-year follow-up / Urban, Istvan A.; Wessing, Bastian; Alandez, Nuria; Meloni, Silvio; Gonzalez-Martin, Oscar; Polizzi, Giovanni; Sanz-Sanchez, Igancio; Montero, Eduardo; Zechner, Werner. - In: CLINICAL ORAL IMPLANTS RESEARCH. - ISSN 0905-7161. - 30:6(2019), pp. 487-497. [10.1111/clr.13426]
Abstract:
Objectives: To compare clinical performance of a novel resorbable non-cross-linked collagen membrane (CXP) with a reference membrane (non-cross-linked resorbable membrane; BG) for simultaneous implant placement and guided bone regeneration (GBR) at dehisced single implant sites. Materials and methods: Preliminary data from this randomized controlled trial were reported previously; this is the 12-month report. The primary outcome measure was defected height at 6 months post-GBR. Secondary outcomes included implant cumulative survival rate (CSR) and success rate since placement; bone level changes, pink esthetic score (PES), and patient satisfaction since definitive prosthesis delivery; patient quality of life since pretreatment; and the 1-year bleeding index. Non-parametric statistical analyses were performed. Results: Among patients, 24 were treated with CXP and 25 with BG. The 1-year implant CSR and success rate were 100% (n = 42). Bone level change between definitive prosthetic delivery and 1 year was not significantly different between the CXP and BG groups (BG + 0.42 mm, CXP + 0.01 mm). The PES increased from 7.55 to 8.10 for the CXP group and from 6.48 to 7.48 for the BG group; 1-year bleeding indices were 0 (16 CXP, 18 BG) and 1 (4 CXP, 2 BG). Patient quality of life changed from an OHIP-14 score of 6.5 at pretreatment to 1.9 at 1 year. Overall satisfaction (visual analogue score) with function and esthetics was 9.9 and 9.7, respectively. Inter-group differences were not significant for assessed outcomes. No device-related adverse events were reported. Conclusions: The use of CXP and BG for simultaneous implant placement and GBR at dehisced implant sites similarly reduced defect height and improved secondary measures, indicating non-inferiority.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
collagen membrane; dehisced implant sites; guided bone regeneration; randomized clinical trial; simultaneous implant placement
Elenco autori:
Urban, Istvan A.; Wessing, Bastian; Alandez, Nuria; Meloni, Silvio; Gonzalez-Martin, Oscar; Polizzi, Giovanni; Sanz-Sanchez, Igancio; Montero, Eduardo; Zechner, Werner
Autori di Ateneo:
MELONI Silvio Mario
Link alla scheda completa:
https://iris.uniss.it/handle/11388/224103
Pubblicato in:
CLINICAL ORAL IMPLANTS RESEARCH