Proof-of-principle results of proton Computed Tomography

Contributo in Atti di convegno
Data di Pubblicazione:
2017
Citazione:
Proof-of-principle results of proton Computed Tomography / Civinini, Carlo; Scaringella, Monica; Bonanno, Danilo; Brianzi, Mirko; Carpinelli, Massimo; Cirrone, G. A. Pablo; Cuttone, Giacomo; Lo Presti, Domenico; Maccioni, Giorgia; Pallotta, Stefania; Randazzo, Nunzio; Romano, Francesco; Rovituso, Marta; Sipala, Valeria; Talamonti, Cinzia; Tommasino, Francesco; Vanzi, Eleonora; Bruzzi, Mara. - 2017-:(2017), pp. 1-6. ( 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016 fra 2016) [10.1109/NSSMIC.2016.8069620].
Abstract:
A proof of principle proton Computed Tomography (pCT) apparatus, based on a silicon microstrip tracker and a YAG:Ce calorimeter, has been manufactured. Tests with a 175 MeV proton beam at The Svedberg Laboratory (TSL, Uppsala, Sweden) aiming at collecting data for reconstructing a tomographic image have been carried out. Algebraic iterative reconstruction methods, together with the most likely path formalism, have been used to obtain non-homogeneous phantom images to eventually extract density and spatial resolutions. The heavy computation load required by the algebraic algorithms has been approached fully exploiting the high calculation parallelism of Graphics Processing Units. The dose delivered to the phantom during the tomographic data-taking has been estimated as well as spatial and density resolutions dependence on dose. An upgraded pCT apparatus with an extended field-of-view able to reconstruct objects of the size of a human head, thus suitable to be used in pre-clinical tests, is now at an advanced construction stage. Using this new apparatus radiographies of an anthropomorphic phantom have been taken at the proton experimental beam line of the 'Trento Proton Therapy Center' (Trento, Italy).
Tipologia CRIS:
4.1 Contributo in Atti di convegno
Keywords:
Radiology, Nuclear Medicine and Imaging; Instrumentation; Nuclear and High Energy Physics; Electronic, Optical and Magnetic Materials
Elenco autori:
Civinini, Carlo; Scaringella, Monica; Bonanno, Danilo; Brianzi, Mirko; Carpinelli, Massimo; Cirrone, G. A. Pablo; Cuttone, Giacomo; Lo Presti, Domenico; Maccioni, Giorgia; Pallotta, Stefania; Randazzo, Nunzio; Romano, Francesco; Rovituso, Marta; Sipala, Valeria; Talamonti, Cinzia; Tommasino, Francesco; Vanzi, Eleonora; Bruzzi, Mara
Autori di Ateneo:
SIPALA Valeria
Link alla scheda completa:
https://iris.uniss.it/handle/11388/211656
Titolo del libro:
2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016