A preliminary report from on physiological bone remodeling on KS versus TSIII implants for molar rehabilitations: a split-mouth, multicenter randomized controlled trial
Academic Article
Publication Date:
2026
Short description:
A preliminary report from on physiological bone remodeling on KS versus TSIII implants for molar rehabilitations: a split-mouth, multicenter randomized controlled trial / Gatti, F., Radoslavova, E., Cacciò, C., Zadrożny, Ł., Martins, O., Scrascia, R., Joób-Fancsaly, Á., Borbéy, J., Meloni, S., Melodia, D., Kormoczi, K., Cervino, G., Gargari, M., Mattia Ceruso, F., Tallarico, M.. - In: ANNALI DI STOMATOLOGIA. - ISSN 1971-1441. - 17:1(2026), pp. 10-19. [10.59987/ads/2026.1.10-19]
abstract:
Objective: To compare the clinical and radiographic outcomes of two implant systems with different implant–abutment connection designs—KS BA (4.0 mm diameter, 15° internal taper) and TS III BA (4.5 mm diameter, 11° internal connection)—used for molar rehabilitation. Materials and Methods: This multicenter, split-mouth, randomized controlled trial involved 42 patients, each receiving one KS and one TSIII implant. Inclusion criteria required healed posterior sites suitable for implants at least 8.5 mm long. Surgeries followed standardized protocols, and patients were rehabilitated with monolithic zirconia crowns bonded to titanium bases. Clinical follow-up was conducted at 6 months after prosthesis delivery. Primary outcomes were implant and prosthesis survival rates and any complications. Marginal bone levels (MBL) were measured radiographically at implant placement, prosthesis delivery, and 6-month follow-up. Patient satisfaction were also recorded. Results: A total of 87 implants (44 KS and 43 TSIII) were placed. At the time of analysis, 27 patients with 53 implants completed the 6-month follow-up. No implant or prosthesis failures and no complications were observed. At prosthesis delivery, mean MBL was 0.32 ± 0.27 mm for TSIII and 0.18 ± 0.32 mm for KS implants (P = 0.029). At 6 months, MBL increased to 0.34 ± 0.27 mm (TSIII) and 0.21 ± 0.32 mm (KS), with a statistically significant difference favoring the KS group (P = 0.034). All patients reported full satisfaction with functional and aesthetic outcomes. Conclusion: The KS implant system demonstrated significantly less marginal bone loss than the TSIII system, despite its narrower diameter. These preliminary findings support the clinical efficacy and mechanical reliability of the KS implant for molar restoration, suggesting it as a viable alternative in posterior sites, especially where bone volume is limited.
Iris type:
1.1 Articolo in rivista
Keywords:
biological width; dental implants; implant-abutment connection; KS implants; marginal bone levels; subcrestal position
List of contributors:
Gatti, Fulvio; Radoslavova, Ekaterina; Cacciò, Carlotta; Zadrożny, Łukasz; Martins, Orlando; Scrascia, Roberto; Joób-Fancsaly, Árpád; Borbéy, Judit; Meloni, Silvio; Melodia, Dario; Kormoczi, Kinga; Cervino, Gabriele; Gargari, Marco; Mattia Ceruso, Francesco; Tallarico, Marco
Published in: