Skip to Main Content (Press Enter)

Logo UNISS
  • ×
  • Home
  • Degrees
  • Courses
  • Jobs
  • People
  • Outputs
  • Organizations
  • Third Mission
  • Expertise & Skills

Logo UNISS

|

UNIFIND

uniss.it
  • ×
  • Home
  • Degrees
  • Courses
  • Jobs
  • People
  • Outputs
  • Organizations
  • Third Mission
  • Expertise & Skills
  1. Outputs

Multi-centre data harmonisation applied to heart-to-mediastinum quantification in parkinsonism (ITA-MIBG): a cross-calibration phantom study with tube and bottle

Academic Article
Publication Date:
2025
Short description:
Multi-centre data harmonisation applied to heart-to-mediastinum quantification in parkinsonism (ITA-MIBG): a cross-calibration phantom study with tube and bottle / Filippi, L., Bianconi, F., Minestrini, M., De Vincentis, G., Frantellizzi, V., Marongiu, A., Ferrari, C., Giordano, A., D'Ambrosio, D., Gazzilli, M., Bertagna, F., Bagni, O., Panareo, S., Guglielmo, P., Lazzarato, A., Casali, M., Aghakhanyan, G., Spanu, A., Evangelista, L., Schillaci, O., et al.. - In: CLINICAL AND TRANSLATIONAL IMAGING. - ISSN 2281-7565. - (2025). [10.1007/s40336-025-00681-4]
abstract:
Purpose: Planar cardiac scintigraphy with [123I]I-mIBG is widely used to image myocardial sympathetic activity. In multicentre studies, different γ-cameras can cause variability in quantitative parameters. This study aimed to harmonise multicentre [123I]I-mIBG data using a custom-designed phantom and to assess its feasibility and acceptability. Methods: A ‘tube and bottle’ phantom was designed to standardise the heart-to-mediastinum (H/M) ratio across 15 centres. Each centre prepared three versions of the phantom (A, B, and C) with varying pertechnetate ([99mTc]Tc-O4-) activities, acquired static images using their own γ-camera, and uploaded DICOM data to a shared platform. In the phantom, the tube and bottle represent the heart and mediastinum, respectively, with the tube-to-bottle (T/B) ratio simulating the H/M ratio. The reference centre analysed the images and calculated the T/B ratios, applying linear regression for data harmonisation. A survey was conducted to assess the phantom’s usability. Results: The harmonised T/B ratios for versions A and B were 20.46 ± 0.78 and 6.19 ± 0.39, respectively. The average slope and intercept of the regression line across the participating centres resulted in 1.07 ± 0.38 and − 0.82 ± 4.95. Survey feedback indicated high feasibility and acceptability, with all centres recommending the phantom for multicentre harmonisation. Conclusions: The custom-made phantom effectively harmonised experimental data across different centres, supporting its use in multicentre studies to improve data consistency.
Iris type:
1.1 Articolo in rivista
Keywords:
Artificial intelligence; Heart-to-mediastinum ratio; Multicentre studies; Radiomics; [; 123; I]I-mIBG; Γ-camera
List of contributors:
Filippi, Luca; Bianconi, Francesco; Minestrini, Matteo; De Vincentis, Giuseppe; Frantellizzi, Viviana; Marongiu, Andrea; Ferrari, Cristina; Giordano, Alessia; D'Ambrosio, Daniela; Gazzilli, Maria; Bertagna, Francesco; Bagni, Oreste; Panareo, Stefano; Guglielmo, Priscilla; Lazzarato, Achille; Casali, Massimiliano; Aghakhanyan, Gayane; Spanu, Angela; Evangelista, Laura; Schillaci, Orazio; Palumbo, Barbara
Authors of the University:
MARONGIU Andrea
SPANU Angela
Handle:
https://iris.uniss.it/handle/11388/358489
Published in:
CLINICAL AND TRANSLATIONAL IMAGING
Journal
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.7.0.0