Skip to Main Content (Press Enter)

Logo UNISS
  • ×
  • Home
  • Degrees
  • Courses
  • Jobs
  • People
  • Outputs
  • Organizations
  • Third Mission
  • Expertise & Skills
  • Equipment

Logo UNISS

|

UNIFIND

uniss.it
  • ×
  • Home
  • Degrees
  • Courses
  • Jobs
  • People
  • Outputs
  • Organizations
  • Third Mission
  • Expertise & Skills
  • Equipment
  1. Outputs

Accuracy of newly developed sleeve-designed templates for insertion of dental implants: a prospective multicenters clinical trial

Academic Article
Publication Date:
2019
Short description:
Accuracy of newly developed sleeve-designed templates for insertion of dental implants: a prospective multicenters clinical trial / Tallarico, M., Kim, Y.-J., Cocchi, F., Martinolli, M., Meloni, S.M.. - In: CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH. - ISSN 1523-0899. - 21:1(2019), pp. 108-113. [10.1111/cid.12704]
abstract:
Background: The insertion of dental implants by means of computer-assisted template-based surgery is an established method. Purpose: To investigate the accuracy of a newly developed sleeve-designed template and to evaluate differences between maxillary and mandibular implants as well as anterior versus posterior area. Materials and Methods: Any partially edentulous patients requiring at least one implant to be planned on three-dimensional cone beam computed tomography scan, according to a computer-assisted template-based protocol, were consecutively enrolled at two centers. Any potential implant position was considered eligible for the present trial. Outcome measures were: implant failure, complications, and accuracy. Results: A total of 39 patients with 119 implants were evaluated. No patients dropped out during the study period (mean follow-up 12.4 ± 7.1 months). Three implants failed at centre two, whereas, one complication was experienced at centre one (limited access in posterior area). Differences were not statistically significant (P >.05). The mean deviations were 0.53 ± 0.46 mm (range 0.05-3.38 mm; 95% CI 0.32-0.48 mm) in the horizontal plan (mesio-distal); 0.42 ± 0.37 mm (range 0.0-1.53 mm; 95% CI 0.26-0.40 mm) in the vertical plan (apico-coronal); and 1.43 ± 1.98° (range 0.03-11.8°; 95% CI 0.31-1.01°) in angle. Differences between centers were compared using the nonparametric Mann-Whitney U test (P >.05). More accurate results were found for anterior implants in both horizontal plan and angle. Conclusion: This study showed good precision in all the parameters measured. The results were thus in a range equal to or better than the mean precision found in numerous clinical trials described in the literature. Posterior implants were less accurate because of the use of open sleeves template.
Iris type:
1.1 Articolo in rivista
Keywords:
accuracy; drill guide; guided surgery; implant planning; sleeve; sleeve-designed
List of contributors:
Tallarico, M.; Kim, Y. -J.; Cocchi, F.; Martinolli, M.; Meloni, S. M.
Authors of the University:
MELONI Silvio Mario
TALLARICO Marco
Handle:
https://iris.uniss.it/handle/11388/224085
Published in:
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH
Journal
  • Overview

Overview

URL

http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1708-8208
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.11.1.0