Skip to Main Content (Press Enter)

Logo UNISS
  • ×
  • Home
  • Degrees
  • Courses
  • Jobs
  • People
  • Outputs
  • Organizations
  • Third Mission
  • Expertise & Skills

Logo UNISS

|

UNIFIND

uniss.it
  • ×
  • Home
  • Degrees
  • Courses
  • Jobs
  • People
  • Outputs
  • Organizations
  • Third Mission
  • Expertise & Skills
  1. Outputs

Use of 2-dimensional speckle-tracking echocardiography to assess left ventricular systolic function in dogs with systemic inflammatory response syndrome

Academic Article
Publication Date:
2019
Short description:
Use of 2-dimensional speckle-tracking echocardiography to assess left ventricular systolic function in dogs with systemic inflammatory response syndrome / Corda, A., PINNA PARPAGLIA, M.L., Sotgiu, G., Zobba, R., Gomez Ochoa, P., Prieto Ramos, J., French, A.. - In: JOURNAL OF VETERINARY INTERNAL MEDICINE. - ISSN 1939-1676. - 33:2(2019), pp. 423-431. [10.1111/jvim.15438]
abstract:
Early identification of systolic dysfunction in dogs with systemic inflammatory response syndrome (SIRS) potentially could improve the outcome and decrease mortality. Objective: To compare 2-dimensional speckle tracking (2D-STE) with 2-dimensional (2D) and M-mode echocardiography in the evaluation of systolic function in SIRS dogs. Animals: Seventeen SIRS and 17 healthy dogs. Methods: Prospective observational case-control study. Each dog underwent physical examination, conventional echocardiography, 2D-STE, and C-reactive protein measurement. Results: Dogs with SIRS had lower 2D-STE ejection fraction (X4D-EF; 44 ± 8 versus 53 ± 8; P =.003), endocardial global longitudinal strain (ENDO-G-Long-St; −14.6 ± 3.2 versus −18.5 ± 4.1; P =.003), and normalized left ventricular diameter in diastole (1.38 ± 0.25 versus 1.54 ± 0.17; P =.04) and systole (0.85 ± 0.18 versus 0.97 ± 0.11; P =.03) as compared to healthy dogs. Simpson method of disks (SMOD) right parasternal EF (55 ± 9 versus 60 ± 6; P =.07) and end systolic volume index (ESVI; 23 ± 10 versus 21 ± 6; P =.61), SMOD left apical EF (59 ± 9 versus 59 ± 6; P =.87) and ESVI (20 ± 8 versus 22 ± 6; P =.25), fractional shortening (FS; 34 ± 5 versus 33 ± 4; P =.39), M-mode EF (64 ± 7 versus 62 ± 5; P =.35), and ESVI (23 ± 11 versus 30 ± 9; P =.06) were not significantly different between SIRS and control group, respectively. Conclusion and Clinical Importance: Speckle tracking X4D-EF and ENDO-G-Long-St are more sensitive than 2D and M-Mode FS, EF, and ESVI in detecting systolic impairment in dogs with SIRS. © 2019 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Iris type:
1.1 Articolo in rivista
Keywords:
canine, cardiovascular monitoring, echocardiography, inflammation
List of contributors:
Corda, Andrea; PINNA PARPAGLIA, Maria Luisa; Sotgiu, Giovanni; Zobba, Rosanna; Gomez Ochoa, Pablo; Prieto Ramos, Jorge; French, Anne
Authors of the University:
CORDA Andrea
PINNA PARPAGLIA Maria Luisa
SOTGIU Giovanni
ZOBBA Rosanna
Handle:
https://iris.uniss.it/handle/11388/219496
Full Text:
https://iris.uniss.it//retrieve/handle/11388/219496/132893/Corda_Speckle_2019.pdf
Published in:
JOURNAL OF VETERINARY INTERNAL MEDICINE
Journal
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.7.2.0