Diagnostic performance of radiologists with and without different CAD systems for mammography

Contributo in Atti di convegno
Data di Pubblicazione:
2003
Citazione:
Diagnostic performance of radiologists with and without different CAD systems for mammography / Lauria, A; Fantacci, Me; Bottigli, U; Delogu, P; Fauci, F; Golosio, Bruno; Indovina, Pl; Masala, Gl; Oliva, Piernicola; Palmiero, R; Raso, G; Stumbo, S; Tangaro, S.. - 5034:(2003), pp. 51-56. ( Medical Imaging 2003: Image Perception, Observer Performance, and Technology Assessment San Diego, CA 18-20 February 2003) [10.1117/12.480079].
Abstract:
The purpose of this study is the evaluation of the variation of performance in terms of sensitivity and specificity of two radiologists with different experience in mammography, with and without the assistance of two different CAD systems. The CAD considered are SecondLook™ (CADx Medical Systems, Canada), and CALMA (Computer Assisted Library in MAmmography). The first is a commercial system, the other is the result of a a research project, supported by INFN (Istituto Nazionale di Fisica Nucleare, Italy); their characteristics have been already reported in literature. To compare the results with and without these tools, a dataset composed by 70 images of patients with cancer (biopsy proven) and 120 images of healthy breasts (with a three years follow up) has been collected. All the images have been digitized and analysed by two CAD, then two radiologists with respectively 6 and 2 years of experience in mammography indipendently made their diagnosis without and with, the support of the two CAD systems. In this work sensitivity and specificity variation, the Az area under the ROC curve, are reported. The results show that the use of a CAD allows for a substantial increment in sensitivity and a less pronounced decrement in specificity. The extent of these effects depends on the experience of the readers and is comparable for the two CAD considered.
Reaxys Database Information
|
Tipologia CRIS:
4.1 Contributo in Atti di convegno
Keywords:
Computer aided diagnosis; Medical imaging
Elenco autori:
Lauria, A; Fantacci, Me; Bottigli, U; Delogu, P; Fauci, F; Golosio, Bruno; Indovina, Pl; Masala, Gl; Oliva, Piernicola; Palmiero, R; Raso, G; Stumbo, S; Tangaro, S.
Link alla scheda completa:
https://iris.uniss.it/handle/11388/72621
Titolo del libro:
Proceedings of SPIE - The International Society for Optical Engineering -
Medical Imaging 2003: Image Perception, Observer Performance, and Technology Assessment
Pubblicato in:
PROCEEDINGS OF SPIE, THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING
Journal
PROCEEDINGS OF SPIE, THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING
Series
  • Dati Generali

Dati Generali

URL

http://dx.doi.org/10.1117/12.480079
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0