Skip to Main Content (Press Enter)

Logo UNISS
  • ×
  • Home
  • Degrees
  • Courses
  • Jobs
  • People
  • Outputs
  • Organizations
  • Third Mission
  • Expertise & Skills

Logo UNISS

|

UNIFIND

uniss.it
  • ×
  • Home
  • Degrees
  • Courses
  • Jobs
  • People
  • Outputs
  • Organizations
  • Third Mission
  • Expertise & Skills
  1. Outputs

Search of microcalcification clusters with the CALMA CAD station

Conference Paper
Publication Date:
2002
Short description:
Search of microcalcification clusters with the CALMA CAD station / Fantacci, M.e., Bottigli, U., Delogu, P., Fauci, F., Golosio, B., Lauria, A., Palmiero, R., Raso, G., Stumbo, S., Tangaro, S.. - 4684:(2002), pp. 1301-1310. (Medical Imaging 2002: Image Processing San Diego, CA 24-28 February 2002) [10.1117/12.467091].
abstract:
CALMA (Computer Assisted Library for MAmmography), a collaboration among physicists and radiologists, has collected a large database of digitized mammographic images (about 5000) and developed a CAD (Computer Aided Detection) which has been integrated in a station which can be used also for digitization, as archive and to perform statistical analysis. In this work we present the results obtained in the automatic search of microcalcification clusters. Images (18×24 cm2, digitized by a CCD linear scanner with a 85 μm pitch and 4096 gray levels) are fully characterized: pathological ones have a consistent description with radiologist's diagnosis and histological data; non pathological ones correspond to patients with a follow up of at least three years. The automated microcalcification clusters analysis is made using an hybrid approach containing both algorithms and neural networks by which are extrated the ROIs (Region Of Interest). These ROIs are indicated on the images and a probability of containing a microcalcification cluster is associated to each ROI. The results obtained with this analysis are described in terms of the ROC (Receiver Operating Characteristic) curve, which shows the tree positive fraction (sensitivity) as a function of the false positive fraction (1-specificity) obtained varying the threshold level of the ROI selection procedure.
Iris type:
4.1 Contributo in Atti di convegno
Keywords:
Computer Aided Detection; Mammography
List of contributors:
Fantacci, Me; Bottigli, U; Delogu, P; Fauci, F; Golosio, Bruno; Lauria, A; Palmiero, R; Raso, G; Stumbo, S; Tangaro, S.
Handle:
https://iris.uniss.it/handle/11388/69743
Book title:
Proceedings of SPIE - The International Society for Optical Engineering -
Medical Imaging 2002: Image Processing
Published in:
PROCEEDINGS OF SPIE, THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING
Journal
PROCEEDINGS OF SPIE, THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING
Series
  • Overview

Overview

URL

http://dx.doi.org/10.1117/12.467091
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.9.3.0