Skip to Main Content (Press Enter)

Logo UNISS
  • ×
  • Home
  • Degrees
  • Courses
  • Jobs
  • People
  • Outputs
  • Organizations
  • Third Mission
  • Expertise & Skills

Logo UNISS

|

UNIFIND

uniss.it
  • ×
  • Home
  • Degrees
  • Courses
  • Jobs
  • People
  • Outputs
  • Organizations
  • Third Mission
  • Expertise & Skills
  1. Outputs

Minimally Invasive Treatment of Lateral Incisors with Guided One-Piece or Two-Piece Titanium-Made Narrow Diameter Implants: A Retrospective Comparative Study with Up to Two Years Follow-Up

Academic Article
Publication Date:
2023
Short description:
Minimally Invasive Treatment of Lateral Incisors with Guided One-Piece or Two-Piece Titanium-Made Narrow Diameter Implants: A Retrospective Comparative Study with Up to Two Years Follow-Up / Zadrozny, L., Gorski, B., Baldoni, E., Lumbau, A.I., Meloni, S.M., Pisano, M., Tallarico, M.. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - 12:11(2023). [10.3390/jcm12113711]
abstract:
Restoring teeth with dental implants has become the gold standard in recent years, especially in the esthetic zone. However, limited amount of available bone as well as limited interdental space in the anterior zone may create problems for implant treatment. Narrow diameter implants (NDI) may be a treatment option to resolve the above-mentioned limitations and providing minimally invasive implant therapy without additional regenerative procedures. In this retrospective study, a comparison of clinical and radiographic outcomes between one-piece and two-piece titanium-made NDIs was done with the follow-up of two years after loading. Twenty-three NDI cases were analyzed, 11 in the one-piece implant group (group one) and 12 in the two-piece implant group (group two). The outcomes were implant and prosthetic failures, any complications occurred, peri-implant bone level changes, and as well as the Pink Esthetic score. No implant or prosthetic failures, as well as, no complications were reported at the two-year follow-up examination. At the same time the marginal bone loss was 0.23 ± 0.11 in the group one and 0.18 ± 0.12 in the group two. Difference was not statistically significant (p = 0.3339). The Pink Esthetic Score, recorded two years after definitive loading, was 12.6 ± 0.97 in the group one and 12.2 ± 0.92 in the group two, with no statistically significant difference between groups (p = 0.3554). With the limitations of the present study, including the small sample size and short follow-up, it is possible to conclude that either one and two-piece NDI can be successfully used to restore lateral incisors with comparable results within the two years of follow-up.
Iris type:
1.1 Articolo in rivista
Keywords:
esthetics; MBL; narrow diameter implants; NDI; one-piece implant; PES; two-piece implants
List of contributors:
Zadrozny, L.; Gorski, B.; Baldoni, E.; Lumbau, A. I.; Meloni, S. M.; Pisano, M.; Tallarico, M.
Authors of the University:
BALDONI Edoardo
MELONI Silvio Mario
TALLARICO Marco
Handle:
https://iris.uniss.it/handle/11388/324395
Published in:
JOURNAL OF CLINICAL MEDICINE
Journal
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.9.0.0