Skip to Main Content (Press Enter)

Logo UNISS
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze

Logo UNISS

|

UNIFIND

uniss.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze
  1. Pubblicazioni

Safety, efficacy, and reproducibility of cavotricuspid isthmus ablation guided by the ablation index: Acute results of the FLAI study

Articolo
Data di Pubblicazione:
2021
Citazione:
Safety, efficacy, and reproducibility of cavotricuspid isthmus ablation guided by the ablation index: Acute results of the FLAI study / Viola, G., Stabile, G., Bandino, S., Rossi, L., Marrazzo, N., Pecora, D., Bottoni, N., Solimene, F., Schillaci, V., Scaglione, M., Ocello, S., Baiocchi, C., Santoro, A., Donzelli, S., De Ruvo, E., Lavalle, C., Sanchez-Gomez, J.M., Pastor, J.F.A., Grandio, P.C., Ferraris, F., et al.. - In: EUROPACE. - ISSN 1099-5129. - 23:2(2021), pp. 264-270. [10.1093/europace/euaa215]
Abstract:
Aims: Ablation index (AI) is a marker of lesion quality during catheter ablation that incorporates contact force, time, and power in a weighted formula. This index was originally developed for pulmonary vein isolation as well as other left atrial procedures. The aim of our study is to evaluate the feasibility and efficacy of the AI for the ablation of the cavotricuspid isthmus (CTI) in patients presenting with typical atrial flutter (AFL). Methods and results: This prospective multicentre non-randomized study enrolled 412 consecutive patients with typical AFL undergoing AI-guided cavotricuspid isthmus ablation. The procedure was performed targeting an AI of 500 and an inter-lesion distance measurement of ≤6 mm. The primary endpoints were CTI 'first-pass' block and persistent block after a 20-min waiting time. Secondary endpoints included procedural and radiofrequency duration and fluoroscopic time. A total of 412 consecutive patients were enrolled in 31 centres (mean age 64.9 ± 9.8; 72.1% males and 27.7% with structural heart disease). The CTI bidirectional 'first-pass' block was reached in 355 patients (88.3%), whereas CTI block at the end of the waiting time was achieved in 405 patients (98.3%). Mean procedural, radiofrequency, and fluoroscopic time were 56.5 ± 28.1, 7.8 ± 4.8, and 1.9 ± 4.8 min, respectively. There were no major procedural complications. There was no significant inter-operator variability in the ability to achieve any of the primary endpoints. Conclusion: AI-guided ablation with an inter-lesion distance ≤6 mm represents an effective, safe, and highly reproducible strategy to achieve bidirectional block in the treatment of typical AFL.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
Ablation index; Atrial flutter; Cavotricuspid isthmus; Inter-distance lesion
Elenco autori:
Viola, G.; Stabile, G.; Bandino, S.; Rossi, L.; Marrazzo, N.; Pecora, D.; Bottoni, N.; Solimene, F.; Schillaci, V.; Scaglione, M.; Ocello, S.; Baiocchi, C.; Santoro, A.; Donzelli, S.; De Ruvo, E.; Lavalle, C.; Sanchez-Gomez, J. M.; Pastor, J. F. A.; Grandio, P. C.; Ferraris, F.; Castro, A.; Rebellato, L.; Marchese, P.; Adao, L.; Primo, J.; Barra, S.; Casu, G.
Autori di Ateneo:
CASU Gavino
SCAGLIONE Mariano
Link alla scheda completa:
https://iris.uniss.it/handle/11388/323769
Pubblicato in:
EUROPACE
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.6.0.0