A new sutureless technique for end-to-end and end-to-side arterial and prosthetic anastomosis

Abstract
Data di Pubblicazione:
2009
Citazione:
A new sutureless technique for end-to-end and end-to-side arterial and prosthetic anastomosis / Sessa, C.; Porcu, P.; Careddu, Giovanni Mario; Manunta, Maria Lucia Gabriella M.; Masala, G.; Magne, J. L.; Cinquin, P.; SANNA PASSINO, Eraldo. - In: BRITISH JOURNAL OF SURGERY. - ISSN 1365-2168. - 96:S5(2009), pp. 46-47.
Abstract:
Introduction: We report a new sutureless anastomosis with stents and grafts currently used in vascular surgery.
Methods and techniques: End-to-end or end-to-side anastomosis using ballon or self-expanding stents were used in 32 sheeps. The graft was places outside the artery and a stent was deployed and fixed with banding silk threads. Clamping time, blood loss and anastomosis patency were studied.
Results: In aortic group (10), all the anastomosis were end-to-end and suturless in 5 cases. No thrombosis was observed at time of animal sacrifice. In carotid group (22), bypasses were done with ballon (22) and self-expanding (18) stents. Forty anastomosis were sutureless including 34 end-to-end and 6 end-to-side. Mean clamping time: 13 min (11–16 min) versus 19 min (17–22 min); blood loss: 0 ml versus 57 ml (47–80 ml) respectively for traditional and sutureless anastomosis. All the ballon-expandable stent (22) thrombosed, due to external compression of the neck against the feeding trough. All 6 self-expanding stents were patent.
Conclusion: Despite a high rate of thrombosis with ballon-expandable stents, sutureless anastomosis technique is effective with a shorter completion time and less bleeding compared to traditional anastomosis. Further device evaluation and improvements are needed to combine laparoscopic and endovascular techniques.
Tipologia CRIS:
1.5 Abstract in rivista
Elenco autori:
Sessa, C.; Porcu, P.; Careddu, Giovanni Mario; Manunta, Maria Lucia Gabriella M.; Masala, G.; Magne, J. L.; Cinquin, P.; SANNA PASSINO, Eraldo
Autori di Ateneo:
CAREDDU Giovanni Mario
MANUNTA Maria Lucia Gabriella M.
MASALA Gerolamo
SANNA PASSINO Eraldo
Link alla scheda completa:
https://iris.uniss.it/handle/11388/68541
Pubblicato in:
BRITISH JOURNAL OF SURGERY
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0