Skip to Main Content (Press Enter)

Logo UNISS
  • ×
  • Home
  • Degrees
  • Courses
  • Jobs
  • People
  • Outputs
  • Organizations
  • Third Mission
  • Expertise & Skills
  • Equipment

Logo UNISS

|

UNIFIND

uniss.it
  • ×
  • Home
  • Degrees
  • Courses
  • Jobs
  • People
  • Outputs
  • Organizations
  • Third Mission
  • Expertise & Skills
  • Equipment
  1. Outputs

Four-implant overdenture fully supported by a CAD-CAM titanium bar: A single-cohort prospective 1-year preliminary study

Academic Article
Publication Date:
2016
Short description:
Four-implant overdenture fully supported by a CAD-CAM titanium bar: A single-cohort prospective 1-year preliminary study / Pozzi, A., Tallarico, M., Moy, P.K.. - In: THE JOURNAL OF PROSTHETIC DENTISTRY. - ISSN 0022-3913. - 116:4(2016), pp. 516-523. [10.1016/j.prosdent.2016.03.015]
abstract:
Statement of problem In patients with an altered skeletal maxillomandibular relationship and bone resorption, the rehabilitation of edentulous jaws by combining 4 implants, 2 straight medially and 2 tilted distally, may be preferred to avoid a bone augmentation procedure. Purpose The purpose of this single cohort 1-year prospective study was to evaluate the clinical performance of a 4-implant overdenture fully supported by a computer-aided designed and computer-aided manufactured (CAD-CAM) titanium bar. Material and methods This single cohort prospective study included edentulous participants rehabilitated with a 4-implant overdenture in 1 of the 2 jaws. The outcomes were implant and prosthetic survival and success rates, any biologic and technical complications, periimplant marginal bone loss, changes in the oral health impact profile (OHIP), bleeding on probing, and the plaque index. Results Eighteen participants received 72 implants. One year after implant placement, no implants or prosthesis had failed, and no biologic or technical complications had been observed. At the 1-year follow-up, the mean marginal bone loss was 0.29 ±0.16 mm. The OHIP summary scores demonstrated a significant improvement in oral health-related quality of life. At the 1-year follow-up, positive bleeding was found in 2 participants (11.1%) around 3 implants (4.1%). Three participants (16.6%), accounting for 5 implants (6.9%), showed a slight amount of plaque. Conclusions A 4-implant overdenture supported by a CAD-CAM titanium bar may be a reliable option for the treatment of the edentulous mandible and maxilla over a 1-year period. Oral health-related quality of life significantly improved in all treated participants.
Iris type:
1.1 Articolo in rivista
List of contributors:
Pozzi, A.; Tallarico, M.; Moy, P. K.
Authors of the University:
TALLARICO Marco
Handle:
https://iris.uniss.it/handle/11388/307368
Published in:
THE JOURNAL OF PROSTHETIC DENTISTRY
Journal
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.11.1.0