Skip to Main Content (Press Enter)

Logo UNISS
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze

Logo UNISS

|

UNIFIND

uniss.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze
  1. Pubblicazioni

Transvaginal ultrasound and sonohysterography for assessment of postpartum residual trophoblastic tissue

Articolo
Data di Pubblicazione:
2010
Citazione:
Transvaginal ultrasound and sonohysterography for assessment of postpartum residual trophoblastic tissue / Cosmi, E; Saccardi, C; Litta, P; Nardelli, Gb; Dessole, Salvatore. - In: INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS. - ISSN 0020-7292. - 110(3):(2010), pp. 262-264.
Abstract:
Abstract
OBJECTIVE:
To compare the accuracy of transvaginal ultrasound and sonohysterography (SHG) in diagnosing residual trophoblastic tissue in postpartum women and to assess the adverse effects and complications of the SHG procedure.
METHODS:
A prospective study of patients with postpartum bleeding enrolled for clinical symptoms and signs of residual trophoblastic tissue. All women underwent transvaginal ultrasound and SHG. Uterine cavity curettage was performed in all women and the material collected was sent for pathologic examination.
RESULTS:
Among 84 patients, transvaginal ultrasound revealed residual trophoblastic tissue in 60 women, whereas SHG detected residual trophoblastic tissue in 48 and blood clots in 12. Pathologic examination confirmed trophoblastic tissue in 48 patients and blood clots in 12. Fifteen (17.9%) patients experienced adverse effects after SHG. Thirteen (15.5%) experienced postprocedural fever that resolved with antibiotics. Two women (2.4%) had severe complications of infection: 1 required surgery for peritonitis, which revealed salpingitis and a pelvic abscess; 1 experienced fever and mild abdominal pain that resolved with antibiotics after 10 days of hospitalization.
CONCLUSIONS:
Although SHG showed greater accuracy than transvaginal ultrasound in detecting residual trophoblastic tissue, a high proportion of patients experienced adverse effects.
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Cosmi, E; Saccardi, C; Litta, P; Nardelli, Gb; Dessole, Salvatore
Link alla scheda completa:
https://iris.uniss.it/handle/11388/85509
Pubblicato in:
INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0