Heads-up 3D eye surgery: Safety outcomes and technological review after 2 years of day-to-day use

Articolo
Data di Pubblicazione:
2021
Citazione:
Heads-up 3D eye surgery: Safety outcomes and technological review after 2 years of day-to-day use / Del Turco, C.; D'Amico Ricci, G.; Dal Vecchio, M.; Bogetto, C.; Panico, E.; Giobbio, D. C.; Romano, M. R.; Panico, C.; La Spina, C.. - In: EUROPEAN JOURNAL OF OPHTHALMOLOGY. - ISSN 1120-6721. - (2021), p. 11206721211012856. [10.1177/11206721211012856]
Abstract:
Background: 3D heads-up visualization systems are aimed to improve the surgical experience by providing high-resolution imaging. Objective of our study is to analyze, over a long-time span, the grade of satisfaction and safety of day-to-day 3D surgery compared to standard surgery and to investigate the technical distinctiveness between the heads-up systems currently in use. Methods: In this retrospective observational case series. we reviewed all surgical records of our ophthalmology-dedicated operatory rooms since the arrival of 3D heads-up viewing system, in November 2017. In particular, we compared the procedural complications of 3D-equipped operatory room (3DR) with the standard microscope operatory room (2DR). Moreover, a satisfaction questionnaire was administered to those surgeons shifting on both rooms to test their preferences on seven specific parameters (comfort, visibility, image quality, depth perception, simplicity of use, maneuverability and teaching potential). Results: 5483 eye surgeries were considered. 2777 (50.6%) were performed in 3DR and 2706 (49.3%) in 2DR. Procedural complication rate was comparable in 3DR and 2DR, also when considering different subtypes of surgery. Twelve surgeons (100% of our surgery team) participated in our satisfaction survey, expressing highest satisfaction score for 3D when applied in retina surgery. For cataract surgery, 3D scored best in all the parameters except for facility in use and depth of field perception. Conclusion: Long-term day-to-day use of 3D heads-up visualization systems showed its safety and its outstanding teaching potential in all ophthalmic surgical subtypes, with higher surgeons confidence for retina and cataract surgery.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
cornea/external disease; eyelid disease: cosmetic eyelid and facial surgery; glaucoma; glaucoma incisional surgery; lens/cataract; oculoplastic eyelid/lacrimal disease; pars plana vitrectomy; phacoemulsification; retina; retinal detachment; Scleral buckling; strabismus; strabismus surgery/complications; surgical instruments/special techniques; surgical trauma; trauma; vitreous/endophthalmitis
Elenco autori:
Del Turco, C.; D'Amico Ricci, G.; Dal Vecchio, M.; Bogetto, C.; Panico, E.; Giobbio, D. C.; Romano, M. R.; Panico, C.; La Spina, C.