Development and validation of an ultra performance liquid chromatography tandem mass method for sildenafil and N-desmethyl sildenafil plasma determination and quantification

Articolo
Data di Pubblicazione:
2015
Citazione:
Development and validation of an ultra performance liquid chromatography tandem mass method for sildenafil and N-desmethyl sildenafil plasma determination and quantification / Simiele, M.; Pensi, D.; Pasero, D.; Ivaldi, F.; Rinaldi, M.; Di Perri, G.; Ranieri, V. M.; D'Avolio, A.. - In: JOURNAL OF CHROMATOGRAPHY. B. - ISSN 1570-0232. - 1001:(2015), pp. 35-40. [10.1016/j.jchromb.2015.07.023]
Abstract:
Sildenafil is a selective inhibitor of cGMP-specific type 5 phosphodiesterase (PDE5) used for the treatment of masculine erectile dysfunction and Pulmonary Arterial Hypertension (PAH). Sildenafil causes vasodilatation; relax of the smooth muscle and reduction of pulmonary arterial pressure. In the liver cytocrome P450 metabolizes sildenafil into its active metabolite, N-desmethyl sildenafil. The determination of plasma levels of sildenafil and N-desmethyl sildenafil could be useful for therapy optimization and pharmacokinetic studies. We have developed and validated a new method for the quantification of sildenafil and its metabolite in human plasma by rapid protein precipitation extraction, using an UPLC system, coupled with a tandem mass spectrometric detector (UPLC-MS/MS). The calibration range was fitted at least square model (r2≥0.999), with an accuracy and an intra- and inter-day RSD% (Relative Standard Deviation), both for sildenafil and N-desmethyl sildenafil, lower than 15%, as required by the FDA guidelines; LLOQ, LLOD, ULOQ were 3.9ng/mL, 1.95ng/mL and 1000ng/mL, respectively, for both analytes. Matrix effect, expressed as mean percent deviation of peak areas, was in the range between 2.6% and 5.8%, lower than 15% as required by guidelines. The mean recovery was 83.2 % for sildenafil and 84.5% for N-desmethyl sildenafil. This method has successfully been applied to a clinical pharmacokinetic study of sildenafil and N-desmethyl sildenafil in patients with PAH undergoing cardiac surgery.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
Metabolite; N-desmethyl sildenafil; Sildenafil; Therapeutic drug monitoring; Ultra performance liquid chromatography tandem mass; Chromatography, Liquid; Humans; Limit of Detection; Phosphodiesterase 5 Inhibitors; Reproducibility of Results; Sildenafil Citrate; Tandem Mass Spectrometry
Elenco autori:
Simiele, M.; Pensi, D.; Pasero, D.; Ivaldi, F.; Rinaldi, M.; Di Perri, G.; Ranieri, V. M.; D'Avolio, A.