Skip to Main Content (Press Enter)

Logo UNISS
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze

Logo UNISS

|

UNIFIND

uniss.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze
  1. Pubblicazioni

Clinical diagnostic utility of IP-10 and LAM antigen levels for the diagnosis of tuberculous pleural effusions in a high burden setting

Articolo
Data di Pubblicazione:
2009
Citazione:
Clinical diagnostic utility of IP-10 and LAM antigen levels for the diagnosis of tuberculous pleural effusions in a high burden setting / Dheda, K; VAN ZYL SMIT, Rn; Sechi, Leonardo Antonio; Badri, M; Meldau, R; Symons, G; Khalfey, H; Carr, I; Maredza, A; Dawson, R; Wainright, H; Whitelaw, A; Bateman, Ed; Zumla, A.. - In: PLOS ONE. - ISSN 1932-6203. - 4:3(2009), p. e4689. [doi:10.1371/journal.pone.0004689]
Abstract:
Background: Current tools for the diagnosis of tuberculosis pleural effusions are sub-optimal. Data about the value of new diagnostic technologies are limited, particularly, in high burden settings. Preliminary case control studies have identified IFN-γ-inducible-10kDa protein (IP-10) as a promising diagnostic marker; however, its diagnostic utility in a day-to-day clinical setting is unclear. Detection of LAM antigen has not previously been evaluated in pleural fluid. Methods: We investigated the comparative diagnostic utility of established (adenosine deaminase [ADA]), more recent (standardized nucleic-acid-amplification-test [NAAT]) and newer technologies (a standardized LAM mycobacterial antigen-detection assay and IP-10 levels) for the evaluation of pleural effusions in 78 consecutively recruited South African tuberculosis suspects. All consenting participants underwent pleural biopsy unless contra-indicated or refused. The reference standard comprised culture positivity for M. tuberculosis or histology suggestive of tuberculosis. Principal Findings: Of 74 evaluable subjects 48, 7 and 19 had definite, probable and non-TB, respectively. IP-10 levels were significantly higher in TB vs non-TB participants (p<0.0001). The respective outcomes [sensitivity, specificity, PPV, NPV %] for the different diagnostic modalities were: ADA at the 30 IU/L cut-point [96; 69; 90; 85], NAAT [6; 93; 67; 28], IP-10 at the 28,170 pg/ml ROC-derived cut-point [80; 82; 91; 64], and IP-10 at the 4035 pg/ml cut-point [100; 53; 83; 100]. Thus IP-10, using the ROC-derived cut-point, missed ∼20% of TB cases and mis-diagnosed ∼20% of non-TB cases. By contrast, when a lower cut-point was used a negative test excluded TB. The NAAT had a poor sensitivity but high specificity. LAM antigen-detection was not diagnostically useful. Conclusion: Although IP-10, like ADA, has sub-optimal specificity, it may be a clinically useful rule-out test for tuberculous pleural effusions. Larger multi-centric studies are now required to confirm our findings
Tipologia CRIS:
1.1 Articolo in rivista
Elenco autori:
Dheda, K; VAN ZYL SMIT, Rn; Sechi, Leonardo Antonio; Badri, M; Meldau, R; Symons, G; Khalfey, H; Carr, I; Maredza, A; Dawson, R; Wainright, H; Whitelaw, A; Bateman, Ed; Zumla, A.
Autori di Ateneo:
SECHI Leonardo Antonio
Link alla scheda completa:
https://iris.uniss.it/handle/11388/47031
Pubblicato in:
PLOS ONE
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0