Skip to Main Content (Press Enter)

Logo UNISS
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze

Logo UNISS

|

UNIFIND

uniss.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Competenze
  1. Pubblicazioni

Particle gamma correlations in 12C measured with the CsI(Tl) based detector array CHIMERA

Articolo
Data di Pubblicazione:
2015
Citazione:
Particle gamma correlations in 12C measured with the CsI(Tl) based detector array CHIMERA / Cardella, G; Acosta, L.; Amorini, F.; Auditore, L.; Berceanu, I.; Castoldi, A.; De Filippo, E.; Dell'Aquila, Daniele; Francalanza, L.; Gnoffo, B.; Guazzoni, C.; Lanzalone, G.; Lombardo, Ivano; Minniti, T.; Morgana, E.; Norella, S.; Pagano, A.; Pagano, E. V.; Papa, M.; Pirrone, S.; Politi, G.; Pop, A.; Quattrocchi, L.; Rizzo, F.; Rosato, Elio; Russotto, P.; Trifirò, A.; Trimarchi, M.; Verde, G.; Vigilante, Mariano. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 799:(2015), pp. 64-69. [10.1016/j.nima.2015.07.054]
Abstract:
Abstract The gamma decay of the first excited 4.44 MeV 2+level of 12C, populated by inelastic scattering of proton and 16O beams at various energies was studied in order to test γ-ray detection efficiency and the quality of angular distribution information given by the CsI(Tl) detectors of the 4π CHIMERA array. The γ-decay was measured in coincidence with ejectile scattered particles in an approximately 4π geometry allowing to extract the angular distribution in the reference frame of recoiling 12C target. The typical sin2 (2θ) behavior of angular distribution was observed in the case of 16O beam. Besides that, for the proton beam, in order to explain the observed distribution, the addition of an incoherent flat contribution was required. This latter is the effect of proton spin flip events allowing the population of M=±1 magnetic substates, that is not possible in reactions induced by 16O beam. A comparison with previously collected data, obtained measuring only in and out of plane proton-γ-ray coincidences, confirms the good quality of the angular distribution information given by the apparatus. Possible applications with radioactive beams are outlined. © 2015 Elsevier B.V.
Tipologia CRIS:
1.1 Articolo in rivista
Keywords:
4π detectors; Angular distributions; Gamma decay; Inelastic scattering; Polarization; Instrumentation; Nuclear and High Energy Physics
Elenco autori:
Cardella, G; Acosta, L.; Amorini, F.; Auditore, L.; Berceanu, I.; Castoldi, A.; De Filippo, E.; Dell'Aquila, Daniele; Francalanza, L.; Gnoffo, B.; Guazzoni, C.; Lanzalone, G.; Lombardo, Ivano; Minniti, T.; Morgana, E.; Norella, S.; Pagano, A.; Pagano, E. V.; Papa, M.; Pirrone, S.; Politi, G.; Pop, A.; Quattrocchi, L.; Rizzo, F.; Rosato, Elio; Russotto, P.; Trifirò, A.; Trimarchi, M.; Verde, G.; Vigilante, Mariano
Link alla scheda completa:
https://iris.uniss.it/handle/11388/239522
Pubblicato in:
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT
Journal
  • Dati Generali

Dati Generali

URL

http://www.sciencedirect.com/science/journal/01689002
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0